The intra-observer reproducibility of cardiovascular magnetic resonance myocardial feature tracking strain assessment is independent of field strength
Schuster A, Morton G, Hussain ST, Jogiya R, Kutty S, Asrress KN, Makowski MR, Bigalke B, Perera D, Beerbaum P, Nagel E (2013)
Publication Type: Journal article
Publication year: 2013
Journal
Book Volume: 82
Pages Range: 296-301
Journal Issue: 2
DOI: 10.1016/j.ejrad.2012.11.012
Abstract
Background: Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising novel method for quantification of myocardial wall mechanics from standard steady-state free precession (SSFP) images. We sought to determine whether magnetic field strength affects the intra-observer reproducibility of CMR-FT strain analysis. Methods: We studied 2 groups, each consisting of 10 healthy subjects, at 1.5 T or 3 T Analysis was performed at baseline and after 4 weeks using dedicated CMR-FT prototype software (Tomtec, Germany) to analyze standard SSFP cine images. Right ventricular (RV) and left ventricular (LV) longitudinal strain (EllRV and EllLV) and LV long-axis radial strain (ErrLAX) were derived from the 4-chamber cine, and LV short-axis circumferential and radial strains (EccSAX, ErrSAX) from the short-axis orientation. Strain parameters were assessed together with LV ejection fraction (EF) and volumes. Intra-observer reproducibility was determined by comparing the first and the second analysis in both groups. Results: In all volunteers resting strain parameters were successfully derived from the SSFP images. There was no difference in strain parameters, volumes and EF between field strengths (p > 0.05). In general EccSAX was the most reproducible strain parameter as determined by the coefficient of variation (CV) at 1.5 T (CV 13.3% and 46% global and segmental respectively) and 3 T (CV 17.2% and 31.1% global and segmental respectively). The least reproducible parameter was EllRV (CV 1.5 T 28.7% and 53.2%; 3 T 43.5% and 63.3% global and segmental respectively). Conclusions: CMR-FT results are similar with reasonable intra-observer reproducibility in different groups of volunteers at 1.5 T and 3 T. CMR-FT is a promising novel technique and our data indicate that results might be transferable between field strengths. However there is a considerable amount of segmental variability indicating that further refinements are needed before CMR-FT can be fully established in clinical routine for quantitative assessment of wall mechanics and strain. © 2012 Elsevier Ireland Ltd.
Involved external institutions
How to cite
APA:
Schuster, A., Morton, G., Hussain, S.T., Jogiya, R., Kutty, S., Asrress, K.N.,... Nagel, E. (2013). The intra-observer reproducibility of cardiovascular magnetic resonance myocardial feature tracking strain assessment is independent of field strength. European Journal of Radiology, 82(2), 296-301. https://dx.doi.org/10.1016/j.ejrad.2012.11.012
MLA:
Schuster, Andreas, et al. "The intra-observer reproducibility of cardiovascular magnetic resonance myocardial feature tracking strain assessment is independent of field strength." European Journal of Radiology 82.2 (2013): 296-301.
BibTeX: Download