Arnold C, Pobel C, Osmanlic F, Körner C (2018)
Publication Language: English
Publication Status: Published
Publication Type: Journal article, Original article
Publication year: 2018
Publisher: Emerald Group Publishing Ltd.
Book Volume: 24
Pages Range: 1401 - 1406
Journal Issue: 8
Open Access Link: https://dx.doi.org/10.1108/RPJ-02-2018-0034
Purpose 
The purpose of this study is the introduction and validation of a new 
technique for process monitoring during electron beam melting (EBM).
Design/Methodology/Approach 
In this study, a backscatter electron detector inside the building chamber
 is used for image acquisition during EBM process. By systematic 
variation of process parameters, the ability of displaying different 
topographies, especially pores, is investigated. The results are 
evaluated in terms of porosity and compared with optical microscopy and 
X-ray computed tomography.
Findings 
The method is capable of detecting major flaws (e.g. pores) and gives information about the quality of the resulting component.
Originality/Value 
Image acquisition by evaluating backscatter electrons during EBM process is a
 new approach in process monitoring which avoids disadvantages 
restricting previously investigated techniques.
APA:
Arnold, C., Pobel, C., Osmanlic, F., & Körner, C. (2018). Layerwise monitoring of electron beam melting via backscatter electron detection. Rapid Prototyping Journal, 24(8), 1401 - 1406. https://doi.org/10.1108/RPJ-02-2018-0034
MLA:
Arnold, Christopher, et al. "Layerwise monitoring of electron beam melting via backscatter electron detection." Rapid Prototyping Journal 24.8 (2018): 1401 - 1406.
BibTeX: Download