Cryo-balloon catheter position planning using AFiT

Brost A, Kleinoeder A, Brost A, Bourier F, Koch M, Kurzidim K, Hornegger J, Strobel N (2012)


Publication Type: Conference contribution, Conference Contribution

Publication year: 2012

Journal

Original Authors: Kleinoeder A., Brost A., Bourier F., Koch M., Kurzidim K., Hornegger J., Strobel N.

Book Volume: 8316

Event location: San Diego, CA

Journal Issue: null

DOI: 10.1117/12.911303

Abstract

Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).

Authors with CRIS profile

Involved external institutions

How to cite

APA:

Brost, A., Kleinoeder, A., Brost, A., Bourier, F., Koch, M., Kurzidim, K.,... Strobel, N. (2012). Cryo-balloon catheter position planning using AFiT. In Proceedings of the Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and Modeling. San Diego, CA.

MLA:

Brost, Alexander, et al. "Cryo-balloon catheter position planning using AFiT." Proceedings of the Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and Modeling, San Diego, CA 2012.