Rambach M, Bauer A, Frey L, Friedrichs P, Ryssel H (2005)
Publication Language: English
Publication Type: Journal article
Publication year: 2005
Book Volume: 483-485
Pages Range: 483
Journal Issue: 621
ISBN: 0878499636
Furnace annealing and lamp annealing of aluminum implanted layers in 4H silicon carbide (SiC) were investigated with respect to surface degradation and electrical parameters. A sheet resistance of about 20kΩ/□ was obtained for an aluminum implantation dose of 1.2·1015cm-2 and annealing in the furnace at 1700°C for 30min. For the same implantation dose, lamp annealing at 1770°C for 5min resulted in a three times higher sheet resistance of 60kΩ/□. The surface roughness was best for the lamp system and stayed below 1nm for Al doses lower than 1·10 15 cm-2.
APA:
Rambach, M., Bauer, A., Frey, L., Friedrichs, P., & Ryssel, H. (2005). Annealing of Aluminium Implanted 4H-SiC: Comparison of Furnace and Lamp Annealing. Materials Science Forum, 483-485(621), 483.
MLA:
Rambach, Martin, et al. "Annealing of Aluminium Implanted 4H-SiC: Comparison of Furnace and Lamp Annealing." Materials Science Forum 483-485.621 (2005): 483.
BibTeX: Download