Approaches to needle navigation in interstitial brachytherapy using infrared tracking and radiography

Kreß V, Merten R, Bert C, Strnad V, Fietkau R, Corradini S, Karius A (2026)


Publication Type: Journal article

Publication year: 2026

Journal

Book Volume: 27

Article Number: e70496

Journal Issue: 2

DOI: 10.1002/acm2.70496

Abstract

Background: Intraoperative cone-beam computed tomography (CBCT) provides a valuable option for accurate three-dimensional applicator positioning in gynecologic brachytherapy, but is associated with radiation exposure and increased intervention time especially in case of repeated CBCT imaging being required for creating a sufficient implant arrangement. Purpose: To reduce the need for multiple CBCT scans for corresponding applicator verification, this work proposes two methods for needle path navigation, including corrections of potential bending in situ, by combining infrared tracking with planar x-ray imaging for enabling accurate intraoperative needle guidance. Methods: An examined 200 mm brachytherapy needle was rigidly mounted on an infrared-reflective tracking tool to enable real time tracking. Two planar x-ray images, acquired from varying distinct angles, were used to determine the exact 3D position of the needle tip region via backprojection. A spline was fitted through the obtained coordinates to reconstruct the full needle path. Based on this, only a single initial CBCT scan was required to visualize the predicted needle path within this scan. Additionally, a second approach for needle prediction was presented focusing on only one planar x-ray image by incorporating prior needle bending information from the initial CBCT scan. Both methods were evaluated in preclinical studies and validated against a corresponding ground-truth obtained from CBCT. Results: The proposed method considering two planar x-ray images successfully reconstructed the needle path with deviations of less than 1 mm from the CBCT reference scan, when using at least 20° offset between the x-ray image acquisitions. The single-scan approach, using prior bending information, yielded promising results with deviations at the tip of below 1.3 mm. Conclusions: Both described methods demonstrated their feasibility in preclinical studies, showing potential to improve and accelerate clinical implantation workflows by means of needle navigation in the future.

Authors with CRIS profile

How to cite

APA:

Kreß, V., Merten, R., Bert, C., Strnad, V., Fietkau, R., Corradini, S., & Karius, A. (2026). Approaches to needle navigation in interstitial brachytherapy using infrared tracking and radiography. Journal of Applied Clinical Medical Physics, 27(2). https://doi.org/10.1002/acm2.70496

MLA:

Kreß, Veronika, et al. "Approaches to needle navigation in interstitial brachytherapy using infrared tracking and radiography." Journal of Applied Clinical Medical Physics 27.2 (2026).

BibTeX: Download