Lehmann A (2023)
Publication Type: Journal article
Publication year: 2023
Book Volume: 1056
Article Number: 168568
DOI: 10.1016/j.nima.2023.168568
In this overview article vacuum-based photon detectors are reviewed emphasizing their applications in Cherenkov imaging devices. After the discussion of the basic detector stages such as photo cathode, electron multiplication, and (anode) readout, the status and recent progress with single- and multi-anode dynode photomultipliers (PMTs), hybrid (avalanche) photodetectors and microchannel-plate PMTs are presented. For all of these devices selected examples of their current and planned applications in neutrino, astroparticle, and high energy physics experiments are given. Possible future developments and innovations are also debated. The last part of this review is dedicated to a comparison of important performance parameters like particle detection efficiency, gain inside a magnetic field, rate capability, aging and lifetime issues, and radiation tolerance.
APA:
Lehmann, A. (2023). Status and perspectives of vacuum-based photon detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1056. https://doi.org/10.1016/j.nima.2023.168568
MLA:
Lehmann, Albert. "Status and perspectives of vacuum-based photon detectors." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1056 (2023).