MRI-Guided Motion-Corrected PET Image Reconstruction for Cardiac PET/MRI

Munoz C, Ellis S, Nekolla SG, Kunze KP, Vitadello T, Neji R, Botnar RM, Schnabel JA, Reader AJ, Prieto C (2021)


Publication Type: Journal article

Publication year: 2021

Journal

Book Volume: 62

Pages Range: 1768-1774

Journal Issue: 12

DOI: 10.2967/jnumed.120.254235

Abstract

Simultaneous PET/MRI has shown potential for the comprehensive assessment of myocardial health from a single examination. Furthermore, MRI-derived respiratory motion information, when incorporated into the PET image reconstruction, has been shown to improve PET image quality. Separately, MRI-based anatomically guided PET image reconstruction has been shown to effectively denoise images, but this denoising has so far been demonstrated mainly in brain imaging. To date, the combined benefits of motion compensation and anatomic guidance have not been demonstrated for myocardial PET/MRI. This work addressed this lack by proposing a single cardiac PET/MR image reconstruction framework that fully utilizes MRI-derived information to allow both motion compensation and anatomic guidance within the reconstruction. Methods: Fifteen patients underwent an18F-FDG cardiac PET/MRI scan with a previously introduced acquisition framework. The MRI data processing and image reconstruction pipeline produces respiratory motion fields and a high-resolution respiratory motion-corrected MR image with good tissue contrast. This MRI-derived information was then included in a respiratory motion- corrected, cardiac-gated, anatomically guided image reconstruction of the simultaneously acquired PET data. Reconstructions were evaluated by measuring myocardial contrast and noise and were compared with images from several comparative intermediate methods using the components of the proposed framework separately. Results: Including respiratory motion correction, cardiac gating, and anatomic guidance significantly increased contrast. In particular, myocardium- to-blood pool contrast increased by 143% on average (P < 0.0001), compared with conventional uncorrected, non guided PET images. Furthermore, anatomic guidance significantly reduced image noise, by 16.1%, compared with nonguided image reconstruction (P < 0.0001). Conclusion: The proposed framework for MRI-derived motion compensation and anatomic guidance of cardiac PET data significantly improvedimagequalitycomparedwithalternativereconstructionmethods. Each component of the reconstruction pipeline had a positive impact on the final image quality. These improvements have the potential to improve clinical interpretability and diagnosis based on cardiac PET/MR images. COPYRIGHT

Involved external institutions

How to cite

APA:

Munoz, C., Ellis, S., Nekolla, S.G., Kunze, K.P., Vitadello, T., Neji, R.,... Prieto, C. (2021). MRI-Guided Motion-Corrected PET Image Reconstruction for Cardiac PET/MRI. Journal of Nuclear Medicine, 62(12), 1768-1774. https://doi.org/10.2967/jnumed.120.254235

MLA:

Munoz, Camila, et al. "MRI-Guided Motion-Corrected PET Image Reconstruction for Cardiac PET/MRI." Journal of Nuclear Medicine 62.12 (2021): 1768-1774.

BibTeX: Download