Lenardo BG, Hardy CA, Tsang RH, Nzobadila Ondze JC, Piepke A, Triambak S, Jamil A, Adhikari G, Al Kharusi S, Angelico E, Arnquist IJ, Belov V, Bernard EP, Bhat A, Bhatta T, Bolotnikov A, Breur PA, Brodsky JP, Brown E, Brunner T, Caden E, Cao GF, Cao L, Chana B, Charlebois SA, Chernyak D, Chiu M, Cohen JR, Collister R, Dalmasson J, Daniels T, Darroch L, Devoe R, Di Vacri ML, Ding YY, Dolinski MJ, Echevers J, Eckert B, Elbeltagi M, Fabris L, Fairbank D, Fairbank W, Farine J, Fu YS, Gallina G, Gautam P, Giacomini G, Gillis W, Gingras C, Gornea R, Gratta G, Harouaka K, Heffner M, Hein E, Hößl J, House A, Iverson A, Jiang XS, Karelin A, Kaufman LJ, Krücken R, Kuchenkov A, Kumar KS, Larson A, Leach KG, Leonard DS, Li G, Li S, Li Z, Licciardi C, Lindsay R, MacLellan R, Masbou J, McMichael K, Medina Peregrina M, Mong B, Moore DC, Murray K, Nattress J, Natzke CR, Ngwadla XE, Ni K, Ning Z, Orrell JL, Ortega GS, Ostrovskiy I, Overman CT, Perna A, Pinto Franco T, Pocar A, Pratte JF, Priel N, Raguzin E, Ramonnye GJ, Rasiwala H, Raymond K, Richardson G, Richman M, Ringuette J, Rowson PC, Saldanha R, Sangiorgio S, Shang X, Soma AK, Spadoni F, Stekhanov V, Sun XL, Thibado S, Tidball A, Todd J, Totev T, Tyuka OA, Vachon F, Veeraraghavan V, Viel S, Wamba K, Wang Y, Wang Q, Wei W, Wen LJ, Wichoski U, Wilde S, Wu WH, Yan W, Yang L, Zeldovich O, Zhao J, Ziegler T (2022)
Publication Type: Journal article
Publication year: 2022
Book Volume: 17
Article Number: P07028
Journal Issue: 7
DOI: 10.1088/1748-0221/17/07/P07028
We study a possible calibration technique for the nEXO experiment using a 127Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127Xe and its small Q-value compared to that of 136Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
APA:
Lenardo, B.G., Hardy, C.A., Tsang, R.H., Nzobadila Ondze, J.C., Piepke, A., Triambak, S.,... Ziegler, T. (2022). Development of a 127Xe calibration source for nEXO. Journal of Instrumentation, 17(7). https://doi.org/10.1088/1748-0221/17/07/P07028
MLA:
Lenardo, B. G., et al. "Development of a 127Xe calibration source for nEXO." Journal of Instrumentation 17.7 (2022).
BibTeX: Download