Automated evaluation of the surface point quality in dimensional X-ray computed tomography

Müller A, Butzhammer L, Wohlgemuth F, Hausotte T (2020)


Publication Language: English

Publication Type: Journal article, Review article

Publication year: 2020

Journal

Book Volume: 87

Pages Range: 111-121

Journal Issue: 2

URI: https://www.degruyter.com/view/j/teme.2020.87.issue-2/teme-2019-0116/teme-2019-0116.xml

DOI: 10.1515/teme-2019-0116

Open Access Link: https://www.degruyter.com/view/j/teme.2020.87.issue-2/teme-2019-0116/teme-2019-0116.xml

Abstract

X-ray computed tomography (CT) enables dimensional measurements of numerous measurands with a single scan, including the measurement of inner structures. However, measurement artefacts complicate the applicability of the technology in some cases. This paper presents a methodology to assess the surface point quality of computed tomography measurements without the requirement of a CAD model. Measurement artefacts lowering the surface point quality can therefore automatically be detected. The correlation of quality values with the random measurement error is demonstrated. The presented method can in principle be used to weight single fit points to reduce the measurement uncertainty of CT measurements.

Authors with CRIS profile

Related research project(s)

How to cite

APA:

Müller, A., Butzhammer, L., Wohlgemuth, F., & Hausotte, T. (2020). Automated evaluation of the surface point quality in dimensional X-ray computed tomography. Technisches Messen, 87(2), 111-121. https://doi.org/10.1515/teme-2019-0116

MLA:

Müller, Andreas, et al. "Automated evaluation of the surface point quality in dimensional X-ray computed tomography." Technisches Messen 87.2 (2020): 111-121.

BibTeX: Download