Z-source inverters, consisting of both inductors and capacitors as DC-link components, provide unique boost capability with simple structure needing no additional switching elements. Due to complex operation modes of the Z-source inverter compared to a conventional inverter, boost operation, light load and regenerating operation cannot be achieved using common space-vector pulse width modulation. This paper proposes a modified SVPWM, derived from the known equations, to overcome this limitation. Besides, equations to control the output behaviour for all operating modes, such as buck, boost and regenerating operation, are given in detail. Finally, experimental results are presented.
APA:
Lechler, M., von Zimmermann, M., & Piepenbreier, B. (2009). Z-Source Drive Inverter using modified SVPWM for low Output Voltage and regenerating Operation. In EPE 2009 Barcelona (pp. paper 0634). Barcelona.
MLA:
Lechler, Martin, Moritz von Zimmermann, and Bernhard Piepenbreier. "Z-Source Drive Inverter using modified SVPWM for low Output Voltage and regenerating Operation." Proceedings of the EPE'09 13th European Conference on Power Electronics and Applications, Barcelona 2009. paper 0634.
BibTeX: Download