Spiecker E (2011)
Publication Status: Published
Publication Type: Journal article
Publication year: 2011
Publisher: Elsevier
Book Volume: 205
Pages Range: 3429-3433
Journal Issue: 11
DOI: 10.1016/j.surfcoat.2010.12.005
Slight variation of the coatings in the ramp layer between Cr and a-C:H resulted in a good or poor adhesion behaviour. Both coatings exhibited in the ramp layer a quasi amorphous matrix structure with short-range ordered substructures. No crystalline chromium carbides could be detected in these regions. Focused investigations of the chemical gradients with Energy Filtered TEM (EFTEM) and Energy Dispersive X-Ray (EDX) spectrometry revealed a clear difference in the chemical composition of the ramp layers. Smooth gradients together with a nanocomposite structure seem to provide a high stability of the ramp layer against delamination. (C) 2010 Elsevier B.V. All rights reserved.
APA:
Spiecker, E. (2011). Microscopic study on the interfacial strength of hydrogenated amorphous carbon coating systems. Surface & Coatings Technology, 205(11), 3429-3433. https://doi.org/10.1016/j.surfcoat.2010.12.005
MLA:
Spiecker, Erdmann. "Microscopic study on the interfacial strength of hydrogenated amorphous carbon coating systems." Surface & Coatings Technology 205.11 (2011): 3429-3433.
BibTeX: Download