Determination of the True Operational Range of a Piezoelectric Actuator


Publication Details
Author(s): Webber K, Franzbach DJ, Koruza J
Publisher: Wiley-Blackwell
Publication year: 2014
Volume: 97
Pages range: 2842-2849
ISSN: 0002-7820

Abstract

Piezoelectric multilayer actuators are technologically important devices used in numerous positioning and force generation applications. During operation, the actuator displacement and force are nonlinearly coupled to the applied electric field, which is often ignored during material characterization. In this study, a novel experimental arrangement is presented that acts like a virtual linear spring, allowing for characterization of the full operational range as a function of applied electric field as well as the true blocking force and impedance matching system stiffness. The macroscopic measurements are contrasted to previous experimental techniques, providing insight into the effect of path dependence on the blocking force.



How to cite
APA: Webber, K., Franzbach, D.J., & Koruza, J. (2014). Determination of the True Operational Range of a Piezoelectric Actuator. Journal of the American Ceramic Society, 97, 2842-2849. https://dx.doi.org/10.1111/jace.13024

MLA: Webber, Kyle, Daniel J. Franzbach, and Jurij Koruza. "Determination of the True Operational Range of a Piezoelectric Actuator." Journal of the American Ceramic Society 97 (2014): 2842-2849.

BibTeX: Download


External Organisations
Share link
Last updated on 2017-09-19 at 03:05
PDF downloaded successfully