Conference contribution


Effective One Step-iterative Fiducial Marker-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees


Publication Details
Author(s): Choi J, Maier A, Berger M, Fahrig R
Title edited volumes: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
Publication year: 2014
Conference Proceedings Title: Proc. SPIE Medical Imaging 2014
Pages range: 9033-36
ISSN: 1605-7422

Event details
Event: SPIE Medical Imaging 2014
Event location: San Diego, California, United States
Start date of the event: 17/02/2014
End date of the event: 20/02/2014

Abstract

We previously introduced three different fiducial marker-based correction methods (2D projection shifting, 2D projection warping, and 3D image warping) for patients’involuntary motion in the lower body during weight-bearing Carm CT scanning. The 3D warping method performed better than 2D methods since it could more accurately take into account the lower body motion in 3D. However, as the 3D warping method applies different rotational and translational movement to the reconstructed image for each projection frame, distance-related weightings were slightly twisted and thus result in overlaying background noise over the entire image. In order to suppress background noise and artifacts (e.g. metallic marker-caused streaks), the 3D warping method has been improved by incorporating bilateral filtering and a Landwebertype iteration in one step. A series of projection images of five healthy volunteers standing at various flexion angles were acquired using a C-arm cone-beam CT system with a flat panel. A horizontal scanning trajectory of the C-arm was calibrated to generate projection matrices. Using the projection matrices, the static reference marker coordinates in 3D were estimated and used for the improved 3D warping method. The improved 3D warping method effectively reduced background noise down below the noise level of 2D methods and also eliminated metal-generated streaks. Thus, improved visibility of soft tissue structures (e.g. fat and muscle) was achieved while maintaining sharp edges at bone-tissue interfaces. Any high resolution weight-bearing cone-beam CT system can apply this method for motion compensation. © 2014 SPIE.



How to cite
APA: Choi, J., Maier, A., Berger, M., & Fahrig, R. (2014). Effective One Step-iterative Fiducial Marker-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees. In Proc. SPIE Medical Imaging 2014 (pp. 9033-36).

MLA: Choi, Jang-Hwan, et al. "Effective One Step-iterative Fiducial Marker-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees." Proceedings of the SPIE Medical Imaging 2014, San Diego, California, United States 2014. 9033-36.

BibTeX: Download


External Organisations
Share link
Last updated on 2017-04-28 at 02:51