Characterization of the temperature and frequency dependency of the complex Poisson’s ratio using a novel combined torsional-axial rheometer

Rodríguez Agudo JA, Haeberle J, Müller-Pabel M, Troiss A, Shetty A, Kaschta J, Giehl C (2023)


Publication Type: Journal article

Publication year: 2023

Journal

Book Volume: 67

Pages Range: 1221-1250

Journal Issue: 6

DOI: 10.1122/8.0000675

Abstract

This study discusses the feasibility of using a combined torsional-axial rheometer to indirectly measure the complex Poisson’s ratio based on shear and Young’s modulus. For this purpose, isothermal frequency sweeps in torsion and extension are performed sequentially on the same cylindrical specimen and under the same environmental conditions. The method is tested on two amorphous polymers, a semicrystalline polymer, a polymer blend, and a copolymer. The article includes an extensive literature review and an uncertainty assessment of the method to provide a basis for subsequent data comparison with existing research. The experimental data show a monotonic increase in the complex Poisson’s ratio up to 0.5 as the temperature approaches α-relaxation for all samples, except for the amorphous polymer. The latter shows a local minimum in the complex Poisson’s ratio observed near α-relaxation, which disappears after thermal annealing of the sample above the α-relaxation temperature. The real and imaginary parts of the complex Poisson’s ratio are additionally determined by evaluating both phase shift angles from torsional and extensional measurements. All polymers show a certain offset between the torsional and extensional phase shift angles in the glassy state, which gradually decreases as the temperature approaches α-relaxation. The complex Poisson’s ratio results are in good agreement with the literature data obtained by existing methods. This confirms that the method is applicable to polymers up to α-relaxation temperatures with significant time savings due to the nondestructive approach. This is of particular interest, given the limited availability of data in the literature.

Authors with CRIS profile

Involved external institutions

How to cite

APA:

Rodríguez Agudo, J.A., Haeberle, J., Müller-Pabel, M., Troiss, A., Shetty, A., Kaschta, J., & Giehl, C. (2023). Characterization of the temperature and frequency dependency of the complex Poisson’s ratio using a novel combined torsional-axial rheometer. Journal of Rheology, 67(6), 1221-1250. https://dx.doi.org/10.1122/8.0000675

MLA:

Rodríguez Agudo, José Alberto, et al. "Characterization of the temperature and frequency dependency of the complex Poisson’s ratio using a novel combined torsional-axial rheometer." Journal of Rheology 67.6 (2023): 1221-1250.

BibTeX: Download