Novel gan half-bridge configuration for the measurement of core losses under rectangular voltages and DC-bias

Stenglein E, Kohlhepp B, Kübrich D, Albach M, Dürbaum T (2020)


Publication Type: Conference contribution

Publication year: 2020

Publisher: Mesago PCIM GmbH

Book Volume: 1

Pages Range: 903-910

Conference Proceedings Title: PCIM Europe Conference Proceedings

Event location: Online

ISBN: 9783800752454

URI: https://ieeexplore.ieee.org/document/9178103

Abstract

An accurate calculation of core losses under rectangular voltages including DC-bias is useful for the design of switched-mode power supplies. Core loss measurements with DC-bias usually impose a DC current and thus DC-bias of the magnetic field strength on ungapped toroids. However, hardware designers require the AC and DC excitation of the magnetic flux density for the results to be of practical use. Therefore, this paper proposes a novel GaN half-bridge configuration to measure core loss under rectangular voltages at high frequencies. A new combination of pulsed operation and iteration method sets the desired DC-bias of the magnetic flux density.

Authors with CRIS profile

How to cite

APA:

Stenglein, E., Kohlhepp, B., Kübrich, D., Albach, M., & Dürbaum, T. (2020). Novel gan half-bridge configuration for the measurement of core losses under rectangular voltages and DC-bias. In PCIM Europe Conference Proceedings (pp. 903-910). Online: Mesago PCIM GmbH.

MLA:

Stenglein, Erika, et al. "Novel gan half-bridge configuration for the measurement of core losses under rectangular voltages and DC-bias." Proceedings of the International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management, PCIM Europe 2020, Online Mesago PCIM GmbH, 2020. 903-910.