What is the hemodynamic effect of the Woven EndoBridge? An in vivo quantification using time-density curve analysis

Gölitz P, Lücking H, Hölter P, Knossalla F, Dörfler A (2020)


Publication Type: Journal article

Publication year: 2020

Journal

DOI: 10.1007/s00234-020-02390-3

Abstract

Purpose: Using the Woven EndoBridge (WEB) for aneurysm treatment has emerged as endovascular approach aiming for flow disruption in aneurysm sac. Since quantifiable data confirming the hemodynamic effect are lacking, we investigated in vivo aneurysmal flow alterations using time-density curve (TDC) analysis. Additionally, we evaluated whether flow parameters could be identified as independent factor to predict aneurysm occlusion. Methods: Forty cerebral aneurysm patients treated with WEB were enrolled. Pre- and postinterventional digital subtraction angiography series were postprocessed and TDCs generated. TDCs were quantified calculating the parameters aneurysmal inflow velocity, outflow velocity, mean flow velocity, and relative time-to-peak (rTTP) of aneurysm filling. Pre- and postinterventional values were compared and related to occlusion rate. Results: WEB implanting induced highly significant rTTP prolongation by 52% (p = 0.001) and highly significant decrease of aneurysmal inflow, outflow, and mean flow velocity (p < 0.001). While outflow velocity was reduced by 49%, inflow velocity was reduced by 33% only. No statistically significant difference between the occluded and the non-occluded group was observed. No flow parameter reached significance level concerning predicting aneurysm occlusion. Conclusion: Flow quantification confirms a significant flow-disrupting effect of WEB reducing more the outflow than the inflow velocity. In our small cohort, no flow parameter reached statistical significance to show predictive value regarding complete aneurysm occlusion. The hemodynamic effect of WEB is on comparable level to flow-diverting stents meaning that aneurysm closure can be delayed. In case of only slight inflow changes and high aneurysmal hemodynamic stress, some aneurysms might not be adequately protected in the short term.

Authors with CRIS profile

How to cite

APA:

Gölitz, P., Lücking, H., Hölter, P., Knossalla, F., & Dörfler, A. (2020). What is the hemodynamic effect of the Woven EndoBridge? An in vivo quantification using time-density curve analysis. Neuroradiology. https://dx.doi.org/10.1007/s00234-020-02390-3

MLA:

Gölitz, Philipp, et al. "What is the hemodynamic effect of the Woven EndoBridge? An in vivo quantification using time-density curve analysis." Neuroradiology (2020).

BibTeX: Download