A continuity equation based optical flow method for cardiac motion correction in 3D PET data

Beitrag bei einer Tagung


Details zur Publikation

Autorinnen und Autoren: Dawood M, Brune C, Jiang X, Büther F, Burger M, Schober O, Schäfers M, Schäfers KP
Herausgeber: Hongen Liao, P.J. Eddie Edwards, Xiaochuan Pan
Titel Sammelwerk: Medical Imaging and Augmented Reality: 5th International Workshop, MIAR 2010, Beijing, China, September 19-20, 2010, Proceedings (Lecture Notes in ... Vision, Pattern Recognition, and Graphics)
Verlag: Springer
Verlagsort: Berlin Heidelberg
Jahr der Veröffentlichung: 2010
Tagungsband: Medical Imaging and Augmented Reality: 5th International Workshop, MIAR 2010, Beijing, China, September 19-20, 2010, Proceedings (Lecture Notes in ... Vision, Pattern Recognition, and Graphics)
Seitenbereich: 88-97
ISBN: 978-3642156984
Sprache: Englisch


Abstract

Cardiac Motion artifacts in PET are a well known problem. The heart undergoes two types of motion, the motion due to respiratory displacement and the motion due to cardiac contraction. These movements lead to blurring of data and to inaccuracies in the quantification. In this study a continuity equation based optical flow method is presented and results on 3D PET patient datasets for cardiac motion correction are presented. The method was evaluated with respect to three criteria: correlation between the images, myocardial thickness and the blood pool activity curves. The results showed that the method was successful in motion correcting the data with high precision.


Einrichtungen weiterer Autorinnen und Autoren

Universitätsklinikum Münster
Westfälische Wilhelms-Universität (WWU) Münster


Zitierweisen

APA:
Dawood, M., Brune, C., Jiang, X., Büther, F., Burger, M., Schober, O.,... Schäfers, K.P. (2010). A continuity equation based optical flow method for cardiac motion correction in 3D PET data. In Hongen Liao, P.J. Eddie Edwards, Xiaochuan Pan (Eds.), Medical Imaging and Augmented Reality: 5th International Workshop, MIAR 2010, Beijing, China, September 19-20, 2010, Proceedings (Lecture Notes in ... Vision, Pattern Recognition, and Graphics) (pp. 88-97). Peking: Berlin Heidelberg: Springer.

MLA:
Dawood, Mohammad, et al. "A continuity equation based optical flow method for cardiac motion correction in 3D PET data." Proceedings of the Proc. of MIAR, Peking Ed. Hongen Liao, P.J. Eddie Edwards, Xiaochuan Pan, Berlin Heidelberg: Springer, 2010. 88-97.

BibTeX: 

Zuletzt aktualisiert 2018-28-11 um 08:53