Evaluating and visualizing the quality of surface points determined from computed tomography volume data

Fleßner M, Müller A, Helmecke E, Hausotte T (2015)


Publication Language: English

Publication Type: Conference contribution

Publication year: 2015

Conference Proceedings Title: PTB open access repository

Event location: Wien

DOI: 10.7795/810.20150223A

Open Access Link: http://public.ptb.de/oa/doi/810_20150223a.pdf

Abstract

By evaluating the volume data in the proximity of a surface point, a Local Quality Value (LQV) is calculated for each surface point of a Computed Tomography (CT) measurement. This allows an automatic and reliable identification of areas containing surface points with reduced accuracy. A colour-coded visualisation of the LQV allows a highlighted display of untrustworthy measurement data. This method is capable of identifying a broad range of artefacts (including beam hardening, noise and rounded off edges) and of points of reduced accuracy due to the fixture of the part on the rotational stage.

Authors with CRIS profile

How to cite

APA:

Fleßner, M., Müller, A., Helmecke, E., & Hausotte, T. (2015). Evaluating and visualizing the quality of surface points determined from computed tomography volume data. In PTB open access repository. Wien.

MLA:

Fleßner, Matthias, et al. "Evaluating and visualizing the quality of surface points determined from computed tomography volume data." Proceedings of the MacroScale 2014 - Recent developments in traceable dimensional measurements, Wien 2015.

BibTeX: Download