Assessment of the single point uncertainty of dimensional CT measurements

Beitrag bei einer Tagung
(Konferenzbeitrag)


Details zur Publikation

Autorinnen und Autoren: Fleßner M, Müller A, Götz D, Helmecke E, Hausotte T
Jahr der Veröffentlichung: 2016
Tagungsband: NDT.net issue Vol.21 No.02
ISSN: 1435-4934
Sprache: Englisch


Abstract


A method analysing the local variations of a series of CT measurements to determine the single point noise is presented. Using a realistic simulation model of the CT system, the mean local offset and the single point uncertainty can additionally be estimated. The method is tested on a measurement series of a micropart. It is shown that the method is capable of identifying areas of increased uncertainty caused by artefacts and of quantifying the value of the single point uncertainty. Additionally, the method is validated using an existing method that is capable of assessing the local quality of a CT measurement.


FAU-Autorinnen und Autoren / FAU-Herausgeberinnen und Herausgeber

Fleßner, Matthias
Lehrstuhl für Fertigungsmesstechnik
Hausotte, Tino Prof. Dr.-Ing.
Lehrstuhl für Fertigungsmesstechnik
Helmecke, Eric
Lehrstuhl für Fertigungsmesstechnik
Müller, Andreas
Lehrstuhl für Fertigungsmesstechnik


Zitierweisen

APA:
Fleßner, M., Müller, A., Götz, D., Helmecke, E., & Hausotte, T. (2016). Assessment of the single point uncertainty of dimensional CT measurements. In NDT.net issue Vol.21 No.02. Wels, AT.

MLA:
Fleßner, Matthias, et al. "Assessment of the single point uncertainty of dimensional CT measurements." Proceedings of the 6th Conference on Industrial Computed Tomography, Wels 2016.

BibTeX: 

Zuletzt aktualisiert 2018-11-08 um 02:43