Translation of Atherosclerotic Plaque Phase-Contrast CT Imaging from Synchrotron Radiation to a Conventional Lab-Based X-Ray Source

Saam T, Herzen J, Hetterich H, Fill S, Willner M, Stockmar M, Achterhold K, Zanette I, Weitkamp T, Schueller U, Auweter S, Adam-Neumair S, Nikolaou K, Reiser MF, Pfeiffer F, Bamberg F (2013)


Publication Type: Journal article

Publication year: 2013

Journal

Book Volume: 8

Article Number: e73513

Journal Issue: 9

DOI: 10.1371/journal.pone.0073513

Abstract

Objectives:Phase-contrast imaging is a novel X-ray based technique that provides enhanced soft tissue contrast. The aim of this study was to evaluate the feasibility of visualizing human carotid arteries by grating-based phase-contrast tomography (PC-CT) at two different experimental set-ups: (i) applying synchrotron radiation and (ii) using a conventional X-ray tube.Materials and Methods:Five ex-vivo carotid artery specimens were examined with PC-CT either at the European Synchrotron Radiation Facility using a monochromatic X-ray beam (2 specimens; 23 keV; pixel size 5.4μm), or at a laboratory set-up on a conventional X-ray tube (3 specimens; 35-40 kVp; 70 mA; pixel size 100 μm). Tomographic images were reconstructed and compared to histopathology. Two independent readers determined vessel dimensions and one reader determined signal-to-noise ratios (SNR) between PC-CT and absorption images.Results:In total, 51 sections were included in the analysis. Images from both set-ups provided sufficient contrast to differentiate individual vessel layers. All PCI-based measurements strongly predicted but significantly overestimated lumen, intima and vessel wall area for both the synchrotron and the laboratory-based measurements as compared with histology (all p<0.001 with slope >0.53 per mm2, 95%-CI: 0.35 to 0.70). Although synchrotron-based images were characterized by higher SNRs than laboratory-based images; both PC-CT set-ups had superior SNRs compared to corresponding conventional absorption-based images (p<0.001). Inter-reader reproducibility was excellent (ICCs >0.98 and >0.84 for synchrotron and for laboratory-based measurements; respectively).Conclusion:Experimental PC-CT of carotid specimens is feasible with both synchrotron and conventional X-ray sources, producing high-resolution images suitable for vessel characterization and atherosclerosis research. © 2013 Saam et al.

Involved external institutions

How to cite

APA:

Saam, T., Herzen, J., Hetterich, H., Fill, S., Willner, M., Stockmar, M.,... Bamberg, F. (2013). Translation of Atherosclerotic Plaque Phase-Contrast CT Imaging from Synchrotron Radiation to a Conventional Lab-Based X-Ray Source. PLoS ONE, 8(9). https://doi.org/10.1371/journal.pone.0073513

MLA:

Saam, Tobias, et al. "Translation of Atherosclerotic Plaque Phase-Contrast CT Imaging from Synchrotron Radiation to a Conventional Lab-Based X-Ray Source." PLoS ONE 8.9 (2013).

BibTeX: Download