CFR-PEEK Pedicle Screw Instrumentation for Spinal Neoplasms: A Single Center Experience on Safety and Efficacy

Joerger AK, Seitz S, Lange N, Aftahy AK, Wagner A, Ryang YM, Bernhardt D, Combs SE, Wostrack M, Gempt J, Meyer B (2022)


Publication Type: Journal article

Publication year: 2022

Journal

Book Volume: 14

Article Number: 5275

Journal Issue: 21

DOI: 10.3390/cancers14215275

Abstract

(1) Background: Surgery for spinal metastases has gained a decisive role in modern oncological treatment. Recently, carbon-fiber-reinforced (CFR) polyethyl-ether-ether-ketone (PEEK) pedicle screw systems were introduced, reducing artifacts on imaging and showing less perturbation effects on photon radiation. Preliminary clinical experience with CFR-PEEK implants for spinal metastases exists. The aim of this monocentric study is to report on the safety and efficacy of CFR-PEEK pedicle screw systems for spinal neoplasms in a large cohort of consecutive patients. (2) Methods: We retrospectively analyzed prospectively the collected data of consecutive patients being operated on from 1 August 2015 to 31 October 2021 using a CFR-PEEK pedicle screw system for posterior stabilization because of spinal metastases or primary bone tumors of the spine. (3) Results: We included 321 patients of a mean age of 65 ± 13 years. On average, 5 ± 2 levels were instrumented. Anterior reconstruction was performed in 121 (37.7%) patients. Intraoperative complications were documented in 30 (9.3%) patients. Revision surgery for postoperative complications was necessary in 55 (17.1%) patients. Implant-related complications, such as intraoperative screw breakage (3.4%) and screw loosening (2.2%), were rare. (4) Conclusions: CFR-PEEK is a safe and efficient alternative to titanium for oncological spinal instrumentation, with low complication and revision rates in routine use and with the advantage of its radiolucency.

Involved external institutions

How to cite

APA:

Joerger, A.-K., Seitz, S., Lange, N., Aftahy, A.K., Wagner, A., Ryang, Y.-M.,... Meyer, B. (2022). CFR-PEEK Pedicle Screw Instrumentation for Spinal Neoplasms: A Single Center Experience on Safety and Efficacy. Cancers, 14(21). https://doi.org/10.3390/cancers14215275

MLA:

Joerger, Ann-Kathrin, et al. "CFR-PEEK Pedicle Screw Instrumentation for Spinal Neoplasms: A Single Center Experience on Safety and Efficacy." Cancers 14.21 (2022).

BibTeX: Download