Ultra-Short-Range Precise Displacement Measurement Setup with a Near Field Slot-Line Antenna and a Dedicated Spiral Calibration

Conference contribution


Publication Details

Author(s): Linz S, Lurz F, Sporer M, Lindner S, Mann S, Weigel R, Kölpin A
Publisher: IEEE
Publication year: 2015
ISBN: 978-1-4799-8275-2
ISSN: 0149-645X
Language: English


Abstract


This work introduces a precise measurement setup for displacement analysis in the near field of a tapered slot-line antenna from 0mm up to 20mm distance. Enhanced accuracy is achieved by a dedicated spiral reconstruction algorithm accounting for the near field effects. Moreover, the precision of the system in the micrometer range is guaranteed by four synchronous 24 bit analog-to-digital converters and a decimation factor of 10, leading to an overall update rate of 1 kHz.



FAU Authors / FAU Editors

Kölpin, Alexander PD Dr.
Lehrstuhl für Technische Elektronik
Lindner, Stefan
Lehrstuhl für Technische Elektronik
Linz, Sarah
Lehrstuhl für Technische Elektronik
Lurz, Fabian
Lehrstuhl für Technische Elektronik
Mann, Sebastian
Lehrstuhl für Technische Elektronik
Sporer, Michael
Lehrstuhl für Technische Elektronik
Weigel, Robert Prof. Dr.-Ing.
Lehrstuhl für Technische Elektronik


How to cite

APA:
Linz, S., Lurz, F., Sporer, M., Lindner, S., Mann, S., Weigel, R., & Kölpin, A. (2015). Ultra-Short-Range Precise Displacement Measurement Setup with a Near Field Slot-Line Antenna and a Dedicated Spiral Calibration. Phoenix, AZ, US: IEEE.

MLA:
Linz, Sarah, et al. "Ultra-Short-Range Precise Displacement Measurement Setup with a Near Field Slot-Line Antenna and a Dedicated Spiral Calibration." Proceedings of the IEEE International Microwave Symposium, Phoenix, AZ IEEE, 2015.

BibTeX: 

Last updated on 2018-10-08 at 14:10