Implant survival and patient satisfaction of reduced diameter implants made from a titanium-zirconium alloy: A retrospective cohort study with 550 implants in 311 patients

Herrmann J, Hentschel A, Glauche I, Vollmer A, Schlegel KA, Lutz R (2016)


Publication Type: Journal article

Publication year: 2016

Journal

Book Volume: 44

Pages Range: 1940-1944

Journal Issue: 12

DOI: 10.1016/j.jcms.2016.09.007

Abstract

The aim of the study was to evaluate implant survival of reduced-diameter implants compared to regular-diameter implants. A retrospective evaluation of 154 Straumann Bone Level Roxolid(®) implants (diameter 3.3 mm) with SLActive(®)-surface in 107 patients, which were inserted between 2009 and 2010 in private practice, was performed. The mean observation period was 22.4 ± 8.2 months. 396 Straumann SLActive(®) implants (4.1 mm and 4.8 mm) in 204 patients, with an observation period of 28.4 ± 10.1 months served as control group. Implant survival rate, resonance frequency analysis and patient satisfaction were evaluated. The implant survival rate was 97.4% in the test vs. 98.5% in the control group. Resonance frequency analysis showed statistically significant lower values for the reduced-diameter implants. Patient satisfaction showed no significant difference between the test and the control group. Reduced-diameter implants displayed high survival rates during the period investigated and represent a convincing treatment alternative. Long-term follow-up investigations confirmed the high implant survival rates of 96.8% (after 69.7 ± 12.3 months) in the test group and 98.5% (after 76.0 ± 13.6 months) in the control group.

Authors with CRIS profile

Involved external institutions

How to cite

APA:

Herrmann, J., Hentschel, A., Glauche, I., Vollmer, A., Schlegel, K.A., & Lutz, R. (2016). Implant survival and patient satisfaction of reduced diameter implants made from a titanium-zirconium alloy: A retrospective cohort study with 550 implants in 311 patients. Journal of Cranio-Maxillofacial Surgery, 44(12), 1940-1944. https://dx.doi.org/10.1016/j.jcms.2016.09.007

MLA:

Herrmann, Jan, et al. "Implant survival and patient satisfaction of reduced diameter implants made from a titanium-zirconium alloy: A retrospective cohort study with 550 implants in 311 patients." Journal of Cranio-Maxillofacial Surgery 44.12 (2016): 1940-1944.

BibTeX: Download