Migration measurement of the cemented Lubinus SP II hip stem - a 10-year follow-up using radiostereometric analysis

Beitrag in einer Fachzeitschrift


Details zur Publikation

Autor(en): Sesselmann S, Hong Y, Schlemmer F, Wiendieck K, Söder S, Hussnaetter I, Müller LA, Forst R, Wierer T
Zeitschrift: Biomedizinische Technik
Jahr der Veröffentlichung: 2016
ISSN: 0013-5585


Abstract


In a previous radiostereometric analysis (RSA) of the Lubinus SP II (Link, Hamburg, Germany), which is one of the most often used cemented hip stems worldwide, our research group detected a very small but statistically significant distal migration of -0.03±0.17 mm 2 years after surgery compared to the postoperative radiograph. Maximum subsidence occurred between 6 and 12 months. The implant appeared to have stabilized after 2 years. The mean value of maximum total point motion (MTPM) was 0.99±0.69 mm, which was detected 2 years after surgery. The purpose of this study was to analyze the migration pattern and to verify the predictive value of short-term RSA of the Lubinus SP II stem after 10 years. After a follow-up of 5 and 10 years, 38 and 27 out of 100 patients remained available for further assessment, respectively. No statistically significant implant translation or rotation was found along or about the axes of the global coordinate system 5 and 10 years after surgery with respect to the postoperative radiograph. Furthermore, the MTPM was stable in both follow-up periods. The results suggest that the Lubinus SP II hip stem is still stable 10 years after surgery, supporting that determining prognosis by short-term RSA follow-up of 2 years could be an appropriate tool for appraisal of implant behavior 10 years after surgery.



FAU-Autoren / FAU-Herausgeber

Forst, Raimund Prof. Dr. med.
Lehrstuhl für Orthopädie mit Orthopädischer Chirurgie
Hong, Yutong
Lehrstuhl für Orthopädie mit Orthopädischer Chirurgie
Müller, Lutz Arne Prof. Dr.
Medizinische Fakultät
Sesselmann, Stefan Dr.
Lehrstuhl für Orthopädie mit Orthopädischer Chirurgie


Autor(en) der externen Einrichtung(en)
Asklepios Kliniken


Zitierweisen

APA:
Sesselmann, S., Hong, Y., Schlemmer, F., Wiendieck, K., Söder, S., Hussnaetter, I.,... Wierer, T. (2016). Migration measurement of the cemented Lubinus SP II hip stem - a 10-year follow-up using radiostereometric analysis. Biomedizinische Technik. https://dx.doi.org/10.1515/bmt-2015-0172

MLA:
Sesselmann, Stefan, et al. "Migration measurement of the cemented Lubinus SP II hip stem - a 10-year follow-up using radiostereometric analysis." Biomedizinische Technik (2016).

BibTeX: 

Zuletzt aktualisiert 2018-06-10 um 02:59