Influence of F0 and Sequence Length of Audio and Electroglottographic Signals on Perturbation Measures for Voice Assessment

Hohm J, Döllinger M, Bohr C, Kniesburges S, Ziethe A (2015)


Publication Type: Journal article

Publication year: 2015

Journal

Book Volume: 29

Pages Range: 517.e11-21

Journal Issue: 4

DOI: 10.1016/j.jvoice.2014.10.001

Abstract

Within the functional assessment of voice disorders, an objective analysis of measured parameters from audio, electroglottographic (EGG), or visual signals is desired. In a typical clinical situation, reliable objective analysis is not always possible due to missing standardization and unknown stability of the clinical parameters. The aim of this study was to investigate the robustness/stability of measured clinical parameters of the audio and EGG signals in a typical clinical setting to ensure a reliable objective analysis. In particular, the influence of F0 and of the sequence length on several definitions of jitter and shimmer will be analyzed.Seventy-four young healthy women produced a sustained vowel /a/ and an upward triad with abrupt changeovers. Different sequence lengths (100, 150, 500, and 1000 ms) of sustained phonation and triads (100 and 150 ms) were extracted from the audio and EGG signals. In total, six variations of jitter and four variations of shimmer parameters were analyzed.Jitter%, Jitter11p, and JitterPPQ of the audio signal as well as Jittermean, Shimmer, and Shimmer11p of the EGG signal are unaffected by both sequence length and F0.Influence of F0 and sequence length on several perturbation measures of the audio and EGG signals was identified. For an objective clinical voice assessment, unaffected definitions of jitter and shimmer should be preferred and applied to enable comparability between different recordings, examinations, and studies.

Authors with CRIS profile

How to cite

APA:

Hohm, J., Döllinger, M., Bohr, C., Kniesburges, S., & Ziethe, A. (2015). Influence of F0 and Sequence Length of Audio and Electroglottographic Signals on Perturbation Measures for Voice Assessment. Journal of Voice, 29(4), 517.e11-21. https://doi.org/10.1016/j.jvoice.2014.10.001

MLA:

Hohm, Julian, et al. "Influence of F0 and Sequence Length of Audio and Electroglottographic Signals on Perturbation Measures for Voice Assessment." Journal of Voice 29.4 (2015): 517.e11-21.

BibTeX: Download