Performance analysis of X-Ray phase-contrast interferometers with respect to grating layouts

Haas W, Bartl P, Bayer F, Durst J, Grund T, Kenntner J, Michel T, Ritter A, Weber T, Anton G, Hornegger J (2010)


Publication Type: Conference contribution, Conference Contribution

Publication year: 2010

Journal

Original Authors: Haas W., Bartl P., Bayer F., Durst J., Grund T., Kenntner J., Michel T., Ritter A., Weber T., Anton G., Hornegger J.

Book Volume: null

Pages Range: 3176-3178

Event location: Knoxville, TN

Journal Issue: null

DOI: 10.1109/NSSMIC.2010.5874388

Abstract

The grating-based phase-contrast imaging approach is highly dependent on the quality of the used gratings. While the fabrication of gratings for the soft X-ray range is more or less well controllable, the fabrication for the hard X-ray range (>30 keV) is more challenging as the gratings must have high aspect ratios and thus fine structures. One of the best fabrication technologies for such gratings is LIGA (Lithography, Electroplating and Molding). However, due to such small structures and high aspect ratio it is unavoidable that the gratings become non-perfect and have deformations. Since the fabrication is complex, expensive and time consuming, a simple way is needed to assess the influence of such deformations on the signal and also a simple way to design and test new grating layouts. This work presents a simulation framework for X-ray phase-contrast imaging which allows to model, simulate and assess the quality of arbitrary grating layouts in an easier, cheaper and faster way. Furthermore, it allows the assessment of the quality of new grating layouts as well as of existing gratings. © 2010 IEEE.

Authors with CRIS profile

Additional Organisation(s)

Involved external institutions

How to cite

APA:

Haas, W., Bartl, P., Bayer, F., Durst, J., Grund, T., Kenntner, J.,... Hornegger, J. (2010). Performance analysis of X-Ray phase-contrast interferometers with respect to grating layouts. In Proceedings of the 2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010 (pp. 3176-3178). Knoxville, TN.

MLA:

Haas, Wilhelm, et al. "Performance analysis of X-Ray phase-contrast interferometers with respect to grating layouts." Proceedings of the 2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010, Knoxville, TN 2010. 3176-3178.

BibTeX: Download